Tender For supply of srphc82364145-poly axial screw for occipito-cervico-thoracic spinalfixation system.used for occipito cervico thoracic spinal fixation and stabilisation in spine trauma, degenerative and tumor surgeries. should be multiaxial self tapping and self drilling in nature with distraction and compression ability. diameter of screws should be available in 3.5mm to 4.5mm with length from 10-32mm in 2mm increments. should have atleast 30 degree angulation in all directions and atleast 45 degree increased angulation at 3 relief notches. should have buttress thread set screw for locking . should be compatible with 3.2/3.5mm titanium or cobalt chrome rods . should becompatible with torque limiting screw driver for final tightening. system should be registered with drug controller general of india. system should be iso or bis or fda or ce approved .[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ]
Tender For supply of srphc82364140-poly axial pedicle screw for single lock spinal system - usedfor dorso lumbosacral fixation and stabilisation in spine trauma, degenerative .pedicular screws should have dual threaded mechanism and should be compatible with 5.5mmtitanium/cobalt chromium rod . screws should be made up of cobalt chromium and available in sizes of 4.5 , 5.5 , 6.5 mm diameter and 25-55mm in length . system should have break off plug mechanism. screw should have an angle of not more than 28 degree between the head and body. system should be compatible minimally invasive surgical technique and also be used along with fenestrated or/and hydroxyapatite coated screws . screws should be colour coded for easy identification. system should be registered with drug controller general of india. system should be iso or bis or fda or ce approved.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ]
Tender For supply of srphc82364155-rigid poly screw for posterior anterior spinal system. used for thoracolumbar fixation and stabilisation in spine trauma, degenerative and tumor surgeries in both anterior and posterior construct. pedicular screws should have a reverse threaded mechanism and should be compatible with 5.5mm titanium rod. screws should be available in sizes of 4.5, 5.5, 6.5 mm diameter and 25-55mm in length. system should have break off plug mechanism.screw should have an angle of not more than 28 degree between the head and body. system should be compatible for minimally invasive surgical technique and also be used along with fenestrated or/and hydroxyapatite coated screws. system should be registered with drug controller general of india. system should be iso or bis or fda or ce approved.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ]